Micro-CT image-derived metrics quantify arterial wall distensibility reduction in a rat model of pulmonary hypertension
- Author(s):
- Johnson,R.H. ( Marquette Univ.,Medical College of Wisconsin,and Zablocki VA Medical Ctr. )
- Karau,K.L.
- Molthen,R.C.
- Haworth,S.T.
- Dawson,C.A.
- Publication title:
- Medical imaging 2000 : physiology and function from multidimensional images, 13-15 February 2000, San Diego, California
- Title of ser.:
- Proceedings of SPIE - the International Society for Optical Engineering
- Ser. no.:
- 3978
- Pub. Year:
- 2000
- Page(from):
- 320
- Page(to):
- 330
- Pub. info.:
- Bellingham, Wash., USA: SPIE - The International Society for Optical Engineering
- ISSN:
- 0277786X
- ISBN:
- 9780819435958 [0819435953]
- Language:
- English
- Call no.:
- P63600/3978
- Type:
- Conference Proceedings
Similar Items:
1
Conference Proceedings
Quantification of pulmonary arterial wall distensibility using parameters extracted from volumetric micro-CT images
SPIE - The International Society for Optical Engineering |
7
Conference Proceedings
Changes in pulmonary arterial wall mechanical properties and lumenal architecture with induced vascular remodeling
SPIE - The International Society of Optical Engineering |
SPIE-The International Society for Optical Engineering |
SPIE-The International Society for Optical Engineering |
3
Conference Proceedings
Semiautomated skeletonization of the pulmonary arterial tree in micro-CT images
SPIE-The International Society for Optical Engineering |
9
Conference Proceedings
Post-acquisition small-animal respiratory gated imaging using micro cone-beam CT
SPIE - The International Society of Optical Engineering |
4
Conference Proceedings
Estimation of pulmonary arterial volume changes in the normal and hypertensive fawn-hooded rat from 3D micro-CT data
SPIE-The International Society for Optical Engineering |
SPIE - The International Society of Optical Engineering |
5
Conference Proceedings
Measuring the effect of airway pressure on pulmonary arterial diameter in the intact rat lung
SPIE-The International Society for Optical Engineering |
11
Conference Proceedings
Stream tube and velocity profile analysis of pulmonary arterial angiograms
SPIE - The International Society for Optical Engineering |
6
Conference Proceedings
Exploiting self-similarity of arterial trees to reduce the complexity of analysis
SPIE - The International Society for Optical Engineering |
12
Conference Proceedings
Labeling the pulmonary arterial tree in CT images for automatic quantification of pulmonary embolism
SPIE - The International Society of Optical Engineering |